Cyber Security News

CISA Releases New ICS Advisories Highlighting Ongoing Threats and Exploits

The Cybersecurity and Infrastructure Security Agency (CISA) has released eight new Industrial Control Systems (ICS) advisories on June 24, 2025, addressing critical vulnerabilities and ongoing threats to essential infrastructure.

These advisories provide detailed technical information and mitigation guidance for a range of ICS products used worldwide.

1.Kaleris Navis N4 Terminal Operating System: Remote Exploits and Data Exposure

Vulnerabilities Identified:

  • Deserialization of Untrusted Data (CWE-502):
    • CVE-2025-2566 — Allows unauthenticated remote code execution through unsafe Java deserialization.
  • Cleartext Transmission of Sensitive Information (CWE-319):
    • CVE-2025-5087 — Enables attackers to extract sensitive information, including plaintext credentials, via insecure HTTP communication.

Risk: Attackers could remotely exploit the system, execute arbitrary code, or extract sensitive credentials.

2.Delta Electronics CNCSoft: Multiple Out-of-Bounds Write Flaws

Vulnerabilities Identified:

  • Out-of-Bounds Write (CWE-787):
    • CVE-2025-47724
    • CVE-2025-47725
    • CVE-2025-47726
    • CVE-2025-47727
      All four vulnerabilities allow code execution if a user opens a malicious file.

Risk: Attackers can execute code within the context of the current process by exploiting file validation flaws.

3.Schneider Electric Modicon Controllers: Input Validation and XSS Risks

Vulnerabilities Identified:

  • Improper Input Validation (CWE-20):
    • CVE-2025-3898
    • CVE-2025-3116
  • Improper Neutralization of Input During Web Page Generation (Cross-site Scripting, CWE-79):
    • CVE-2025-3899
    • CVE-2025-3905
    • CVE-2025-3117
  • Uncontrolled Resource Consumption (CWE-400):
    • CVE-2025-3112

Risk: Successful exploitation could lead to denial-of-service, arbitrary code execution, or unauthorized data manipulation via web interfaces.

4.Schneider Electric EVLink WallBox: Path Traversal and Command Injection

Vulnerabilities Identified:

  • Improper Limitation of a Pathname to a Restricted Directory (Path Traversal, CWE-22):
    • CVE-2025-5740
    • CVE-2025-5741
  • Improper Neutralization of Input During Web Page Generation (Cross-site Scripting, CWE-79):
    • CVE-2025-5742
  • Improper Neutralization of Special Elements used in an OS Command (OS Command Injection, CWE-78):
    • CVE-2025-5743

Risk: Attackers could gain remote control, read or write arbitrary files, or inject malicious code via the web server.

5.ControlID iDSecure On-Premises: Authentication Bypass and SQL Injection

Vulnerabilities Identified:

  • Improper Authentication (CWE-287):
    • CVE-2025-49851
  • Server-Side Request Forgery (SSRF, CWE-918):
    • CVE-2025-49852
  • Improper Neutralization of Special Elements Used in an SQL Command (SQL Injection, CWE-89):
    • CVE-2025-49853

Risk: Exploits could allow attackers to bypass authentication, retrieve sensitive data, or execute arbitrary SQL commands.

6.Parsons AccuWeather Widget: Cross-site Scripting in Utility Portals

Vulnerability Identified:

  • Improper Neutralization of Input During Web Page Generation (Cross-site Scripting, CWE-79):
    • CVE-2025-5015

Risk: Attackers may insert malicious links into RSS feeds, potentially compromising users who access the feed.

7.MICROSENS NMP Web+: Hard-coded Credentials and Path Traversal

Vulnerabilities Identified:

  • Use of Hard-coded, Security-relevant Constants (CWE-547):
    • CVE-2025-49151
  • Insufficient Session Expiration (CWE-613):
    • CVE-2025-49152
  • Improper Limitation of a Pathname to a Restricted Directory (Path Traversal, CWE-22):
    • CVE-2025-49153

Risk: Attackers could bypass authentication, gain persistent access, overwrite files, or execute arbitrary code.

8.Mitsubishi Electric MELSEC-Q Series PLCs (Update B): Resource Exhaustion

Vulnerability Identified:

  • Uncontrolled Resource Consumption (Resource Exhaustion, CWE-400):
    • CVE-2019-6535

Risk: Remote attackers can crash Ethernet and USB communication by sending specially crafted packets.

CISA urges all ICS users and administrators to review these advisories for technical details and apply recommended mitigations to safeguard critical infrastructure from ongoing threats.

Find this News Interesting! Follow us on Google News, LinkedIn, and X to Get Instant Updates

Divya

Divya is a Senior Journalist at GBhackers covering Cyber Attacks, Threats, Breaches, Vulnerabilities and other happenings in the cyber world.

Recent Posts

Hackers Use ConnectWise SkyKick Credentials to Access Microsoft 365, Halting Cloud Backups

Attackers abused compromised ConnectWise Cloud Backup credentials to access Microsoft 365 customer environments, prompting ConnectWise…

1 day ago

Anthropic’s Claude AI Uncovers Origins of NSA-Provided Cryptographic Keys After 25 Years

Anthropic says an internal Claude research model reconstructed how the National Security Agency generated seeds…

2 days ago

Critical WordPress Flaws Allow Attackers to Execute Remote Code Without Authentication

Two WordPress Core vulnerabilities can be chained to execute remote code without authentication, according to…

2 days ago

OpenBSD Kernel Flaw Dating Back 37 Years Enables Local Privilege Escalation to Root

A newly disclosed OpenBSD kernel exploitation chain combines a shared memory accounting flaw with a…

2 days ago

GhostAction Hackers Hide Credential-Stealing Malware in Fake Font Files Across 94 GitHub Repositories

GhostAction attackers have expanded their GitHub credential theft campaign with a second stage that disguises…

2 days ago

SideCopy Hackers Target Indian Organizations With ReverseRAT Malware to Steal Data

Indian authorities have warned that SideCopy hackers are targeting Indian organizations, including academic institutions, with…

2 days ago